Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Care; Maintenance Instructions; Technical Specifications - Kärcher WRP 8000 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für WRP 8000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Monitoring and regulating equipment
Float switch in the recycled water tank
Floater switch in the pump basin
* S5 optional
Immersion pump
Motor output
Voltage
Power consumption
Flow rate at approx. 0.1 MPa (1 bar), approx.
Pressure
Entire unit
Filter capacity
Voltage
Frequency
Weight
Width
Depth
Height

Maintenance and care

Maintenance instructions

The bases of a safe operating of the equip-
ment is the regularly maintenance accord-
ing to the following maintenance plan.
Use only original parts of the manufacturer
or part suggested by him, such as
parts and wearing parts,
accessories parts,
operating materials,
cleaning agents.
DANGER
Risk of accident while working on the unit.
During all tasks
 First switch-on in voltage-less state,
switch off the emergency stop switch
and secure it against being switched on
again.
 Shut off water supply.
18
S7 up
Recycled water tank full. Filling process is stopped.
S7 down
Recycled water tank is filled.
Delay 120 seconds.
S9 up
Switching off the fresh water supply. Indicator lamp "Fresh water supply" lights up yellow.
S9 down
Switching on the fresh water supply. Indicator lamp "Fresh water supply" lights up yellow.
S11 up
Dry run protection for washing system not active, no error message.
S11 down
Dry run protection for washing system active, error message on the washing system.
S5 top*
Pump basin overfilled. Starting the disposal via the recycled water tank into the channel
S5 bottom*
Pump basin is not overfilled, normal system operation.
S14 top
Pump basin full (with option salt water exfiltration).
S14 bottom
No function / switch point is not used
S15 top
Pump basin is not empty, normal system operation.
S15 bottom
Pump basin empty, dry run protection of immersion pump active, no filtration, no re-
flushing possible. System runs on fresh water.

Technical specifications

Who may perform maintenance?
Operator
Work designated with the sign "Opera-
tor" may only be carried out by persons
who have been instructed in the safe
operation and maintenance on washing
systems with recycling unit.
Customer Service
Work designated with the sign "Cus-
tomer Service" may only be done by the
fitters of Kärcher Customer Service.
Maintenance contract
In order to guarantee a reliable operation of
the equipment, we success, you signed a
maintenance agreement. Please refer to
your local Kärcher service department.
W
V
A
m
/h
3
MPa (bar)
m
/h
3
V
Hz
kg
mm
mm
mm
6
-
EN
WRP 8000
WRP 16000
1.217-151.0
1.217-152.0
1300
1700
230/1~
5,9
8,5
8
16
max. 0.14 (1.4) max. 0.16 (1.6)
max. 10
max. 20
230/1~
50
280
390
700
900
620
780
1600

Werbung