Inhaltsverzeichnis
RCMB613
Schalteinrichtung Control Pilot
Ausführung ......................................................................................................................................................................................................................................... Relais 1 x Wechselkontakt
Isolation (Funktionsisolierung) ............................................................................................................................................................................................................................................500 V
Schaltvermögen...........................................................................................................................................................................................................................................AC/DC 24 V, 100 mA
Steuereingänge
Ausführung ........................................................................................................................................................................................................................................... LOW: aktivierter Zustand
...........................................................................................................................................................................................................................................................HIGH: deaktivierter Zustand
Schaltschwellen.......................................................................................................................................................................................................................................................HIGH: < 13 V
................................................................................................................................................................................................................................................................................. LOW: < 0,5 V
Belastbarkeit U
(max) .................................................................................................................................................................................................................................................... DC 12 V
in
Eingangsstrom...............................................................................................................................................................................................................................................................DC 10 mA
Ruhezustand ............................................................................................................................................................................................................................. HIGH (Eingang nicht beschaltet)
Steuerausgänge
Ausführung .......................................................................................................................................................................................................................................OpenCollector oder Kontakt
Spannungsfall................................................................................................................................................................................................................................... < 1 V bei Belastung 10 mA
Belastbarkeit ........................................................................................................................................................................................................................................................ DC 12 V, 25 mA
Leckstrom.........................................................................................................................................................................................................................................................................< 50 μA
Anzeige und Bedienung
LED ................................................................................................................................................................................................................................................................................. grün: ON
....................................................................................................................................................................................................................................................................................... rot: Alarm
Taster geräteintern ..................................................................................................................................................................................................................Umschalten Norm IEC / UL2231*
Umwelt/EMV
Einstellung UL2231
Störfestigkeit..................................................................................................................................................................................................................................... UL2231-2
Störemission ..................................................................................................................................................................................................................................... UL2231-2
Einstellung IEC61851
Störfestigkeit..............................................................................................................................................................................................................................IEC 61000-6-1
Störemission ..............................................................................................................................................................................................................................IEC 61000-6-3
Arbeitstemperatur ............................................................................................................................................................................................................................................... –35...+70 °C
Klimaklassen nach IEC 60721
Ortsfester Einsatz (IEC 60721-3-3) ........................................................................................................................................................................................................................................3K5
Transport (IEC 60721-3-2) .....................................................................................................................................................................................................................................................2K3
Langzeitlagerung (IEC 60271-3-1) ........................................................................................................................................................................................................................................1K4
Mechanische Beanspruchung nach IEC 60271
Ortsfester Einsatz (IEC 60721-3-3) .......................................................................................................................................................................................................................................3M4
Transport (IEC 60721-3-2) ....................................................................................................................................................................................................................................................2M2
Langzeitlagerung (IEC 60271-3-1) .......................................................................................................................................................................................................................................1M3
Anschluss
Anschlussart .......................................................................................................................................................................................................................... Steckverbinder, Schraubklemmen
Anschlussvermögen
Starr /flexibel ............................................................................................................................................................................................................................0,2...2,5 mm² (AWG 24...14)
Flexibel mit Aderendhülse ohne Kunststoffhülse.................................................................................................................................................................0,25...2,5 mm² (AWG 24...14)
Flexibel mit Aderendhülse mit Kunststoffhülse....................................................................................................................................................................0,25...1,5 mm² (AWG 24...16)
Grenzbedingungen externes Lastschütz K0
Spulenspannung............................................................................................................................................................................................................................................................... DC 12 V
Spulenstrom.....................................................................................................................................................................................................................................................Dauerstrom < 2 A
Einschaltstrom ........................................................................................................................................................................................................... < 4 A (unter Worst-Case-Bedingungen)
Kontaktöffnungszeit ...............................................................................................................................................................................................< 10 ms (unter Worst-Case-Bedingungen)
Überspannungsschutz.................................................................................................................................................................................... Freilaufdiode an der Spule (siehe Anschlussbild)
Sonstiges
Betriebsart ................................................................................................................................................................................................................................................................Dauerbetrieb
Lebensdauer..................................................................................................................................................................................................................................................... 10 Jahre bei 40 °C
Schutzart Gehäuse ................................................................................................................................................................................................................................................................IP 30
Schutzart Klemmen ..............................................................................................................................................................................................................................................................IP 20
Schnellbefestigung auf Hutprofilschiene..................................................................................................................................................................................................................... IEC 60715
* = Werkseinstellung