10. Malfunctions - causes and elimination

Display
-0-
_____
-----
Err 04
Err 05
Err 06
Err 07
Err 08
Only for rechargeable battery/battery application:
Display
LO
If the faults cannot be rectified or other error messages are displayed, please contact your
Soehnle Industrial Solutions service partner.
Description
When switched on, the
The scale automatically sets to
zero. If the scale is outside the
intended tolerance range, the
display shows -0-.
Underload: In the display field
only the lower
horizontal lines.
Overload: In the display field
only the upper horizontal lines.
The maximum weighing range
has been exceeded.
Part weight too small.
Zero setting limit exceeded or
fallen below.
Taring with unloaded
balance and in case of overload
possible.
Printing at underload or overload
Overload not possible.
Switching lb/kg locked.
Description
If the battery symbol
is permanently lit: Terminal is in
battery or rechargeable battery or
rechargeable battery operation.
When the full battery symbol
flashes: Battery is charging.
When the empty battery symbol
flashes: Battery is discharged.
Approx. 30 min. of operating time
remain.
Battery is empty.
Remedial action
Take the weight off the scale.
Remove any dirt.
If the scale does not show zero
seconds, please contact your manu-
facturer's service department.
Switch off the scale and switch it
switch on again. The zero point is
automatically reset.
Remove part of the load from the
Remove from the scale
Remedial action
Connect the unit to the mains adapter
and Charge terminal for 8 hours.
Connect the unit to the mains adapter
and charge terminal for 7 h 45 min.