8.
Optional functions

8.2 Hold function

HOLD

8.3 Printing / IT connection

40
With the hold function you can freeze a weight value for a certain period of time.
Before you can activate this function, however, you must make sure that the
hold function has been assigned to the freely assignable function button (see
chapter 8.1).
The settings for the hold function are made in the setting mode (see separate
description Terminal 3800: 470.702.136, Terminal 3810: 470.702.134 User Mode
UCAL1 Item 02).
The hold function is not active by default.
The following settings are available:
Hold-Mode
Function
0
Not active
1
At standstill > Empty
2
Max. Value at standstill > Empty Unloading the scale
3
Drag pointer > Empty
In weighing mode, you can either activate or deactivate the hold mode using the
function button.
A printer, a large display or an IT/ PC can be connected to the terminal 3810 with
the optional serial interface (RS232).
The interface function is configured according to the separate descriptions
Terminal 3800: 470.702.136, Terminal 3810: 470.702.134 User mode and
470.508.108 Data interface.
A printout or data set transmission can be triggered with the SEND button or by
request via EDP.
On the 3800 terminal, pressing the SEND key transmits the data set in user mode
to the USB interface.
Setting in USER mode under UCAL 6 Pos 9.
Cancel function
-
Unloading the scale
Unloading the scale