Mold Guard Operation
After the cooling operation is stopped, the fan of the indoor unit is dried by heating or fan mode to
suppress the generation of mold inside the indoor unit.
- Mold Guard Operation period is about 100 minutes.
- It can't remove mold or sterilize.
Cooling or Dehumidify
operation
Running
 "
" Lamp on the indoor unit lights up during Mold Guard operation.
 If the air conditioner is operated in cooling or drying mode, including in auto mode, for more than 10
minutes and then put into off mode, the mold guard operation will start.
 If unit operation is stopped after heating operation, Mold Guard will not operate.
 Room temperature or humidity may rise.
NOTE
If unit operation is stopped after heating operation, Mold Guard will not operate.
If operation of Unit is stop by Off Timer , the Mold Guard will not operate.
If On Timer is set and on time is within about 2 hours, the Mold Guard will not operate.
Depending on situation, Mold Guard will operate with Fan Mode.
Room temperature or humidity may rise.
When there would be the window near indoor unit, the water might condense on the window during Mold
Guard. If necessary, to cancel Mold Guard.
The Process of Mold Guard
More than 10 min.
Mold Guard
The upper and lower deflector(s) remain open
Stop
How to set and cancel Mold Guard
For setting
 Press the room temperature Up button
button for 3 seconds together while remote controller in OFF mode
1
with directing remote control towards indoor unit.
"
" is displayed on the LCD.
For cancelling
 Press the room temperature Up button
button for 3 seconds together while remote controller in OFF mode
with directing remote control towards indoor unit.
"
" is disappear on the LCD.
2
 Once Mold Guard function set, Mold Guard icon will always display on
the LCD. And it stored in the memory of remote controller and remain
set even after reset or battery replacement case. It is one time setting
procedure to use this function.
■ How to stop at middle point of Mold Guard operation
 Press the
button (On/Off) twice, the operation will stop.
3
 "
" Lamp on the indoor unit turns off. But setting for Mold Guard will
not cancel, it will stop operation only.