Herunterladen Inhalt Inhalt Diese Seite drucken

Ventilation And Safety Distances - KKT KOLBE IND7704DRAFT Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für IND7704DRAFT:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation

10.2 Ventilation and safety distances

• Make absolutely sure that the following conditions are met
for adequate ventilation of the hob
and that the supply and exhaust air is not blocked:
A
B
C
D
A (mm)
min. 760 (Hanging furniture)
• The safety distance from the hob to wall units, shelves etc. han-
ging above the hob must be at least 760 mm.
• If the hob is installed above an oven, the oven must have its own
fan.
The safety distance between the bottom of the hob and the oven
must be at least 50 mm.
• The installation must comply with all distance regulations and
other regulations.
E
B (mm)
min. 50
C (mm)
D
Air gap /
min. 20
intake
min.30mm
E
Exhaust air
min. 5mm
41