TROUBLESHOOTING

Issue:
Generator switch in the off " 0 " Turn the generator switch to the
Choke knob in the wrong position
Bad or contaminated fuel
Not enough oil in the engine
Engine Will
Not Start
No fuel at the carburetor
For electric start, start the engine battery. If the battery is providing
If the engine still will not start:
Engine Runs
Rough (no
Choke knob in the wrong position
load)
If the engine still runs rough:
Not enough oil in the engine
Engine Shuts
Down
If the engine still shuts down:
Engine Runs
Rough (with
load)
Defective device plugged in
If the engine still runs rough:
Engine Runs,
But Generator
Does Not
Provide
Power
Defective device plugged in
Possible Cause:
position
No fuel
Dirty air filter
Engine flooded
No spark
using the recoil starter.
Dirty air filter
Out of fuel
Dirty air filter
Generator overloaded
Dirty air filter
Generator overloaded
Circuit breaker is open
Bad connection
Defective power cord
If there is still no power:
Solution:
correct position.
Place the choke knob in the
correct position.
Fill the fuel tank.
Check the fuel.
Check the oil level. If low, add
the recommended oil.
Clean the air filter.
Make sure the fuel switch is in
the on " I " position.
Wait 5 minutes.
Replace the spark plug.
If the generator starts, check the
less than 12.4 volts, replace the
battery.
Take the unit to an authorized service provider.
Stop the engine and check the
air filter. Clean if needed.
Place the choke knob in the
correct position.
Take the unit to an authorized service provider.
Check the fuel. Fill the tank if
necessary.
Check the oil level. If low, add
the recommended oil.
Clean the air filter.
Unplug some of the devices.
Take the unit to an authorized service provider.
Stop the engine and check the
air filter. Clean if needed.
Unplug some of the devices.
Unplug defective device.
Take the unit to an authorized service provider.
Close the circuit breaker.
Stop the engine and check the
connections.
Replace the cord.
Unplug defective device.
Take the unit to an authorized service provider.
-
17
-
Check:
Start the engine.
Start the engine /
check if it runs rough
Start the engine /
check if it shuts down.
Start the engine /
check if it runs rough.
Start the engine /
check for power.