Walk-Around Inspection

1. Remove the side panel.
2. Remove the spark plug cap (3).
3. Use the plug wrench (1) to remove the spark plug.
4. Visually check the spark plug to see if it is damaged. If the insulator is cracked,
replace the spark plug. If the electrode is damaged, replace the spark plug.
5. Measure the plug gap (4) with a feeler gauge. Adjust the gap as necessary by
carefully bending the side electrode. Refer to Specifications for the correct gap for
your product.
6. Check the spark plug washer to ensure proper working condition. If the washer is
damaged, replace the washer.
7. Install spark plug and tighten to 16 ± 2 lb ft (22 ± 2 Nm). DO NOT over tighten as
this may damage the engine.
Before starting the engine perform a visual inspection of the unit. Look for:
 Proper oil level
 Proper fuel level
 Good quality fuel
 Fluid leaks
 Loose clamps
 Loose bolts
 Cracked fuel line
 Loose or frayed wiring
 Built up debris
In addition, make sure that:
 The ground strap is properly connected
 The circuit breakers are in OFF

STORAGE

When a generator is in storage, moisture may condense in the windings. In order to
minimize condensation, always store the generator in a dry area. Cover the generator with
a protective cover that extends to the ground. The cover should remain loose around the
generator in order to allow proper ventilation.

Storage for 1 to 3 months

Remove any dirt, rust, grease, and oil from the generator. DO NOT use a pressure washer
to clean the generator. Inspect the exterior. Make any necessary repairs.
Add fuel stabilizer to the fuel tank to prevent the gasoline from going bad. Start and run the
engine for 10 minutes to ensure that the fuel stabilizer has been pulled in to the carburetor.
Shut off the engine and allow the engine to cool.
Turn the fuel valve to the off "OFF" position.
Move the generator to the storage place. Cover the generator.

Storage for more than 3 months

Remove any dirt, rust, grease, and oil from the generator. DO NOT use a pressure washer
to clean the generator. Inspect the exterior. Make any necessary repairs.
"OFF"position.
-
15
-