 Do not use gasoline with greater than 10% ethanol content.
 Do not use old gasoline.
 Avoid getting dirt or water into the fuel tank.

Walk-Around Inspection

Perform the Walk-Around Inspection before each use as described later in this manual.

STARTING THE ENGINE

Recoil Start

1. Isolate the generator from the utility
2. Unplug any electrical devices from the receptacles.
3. Turn the fuel switch to the on "ON" position.
4. Turn the AC circuit breakers to the off "OFF" position
5. If the engine is cold, turn the choke knob to be closed.
6. Turn the generator switch to the on "ON" position.
7. Slowly pull the starter handle until resistance is felt, then quickly pull the starter
handle the rest of the way. If the engine does not start, repeat step 7 until the engine
does start.
8. After the engine has warmed, turn the choke knob to be open.
9. Turn the AC circuit breaker to the on "ON" position.

Electric Start (If equipped)

1. Isolate the generator from the utility
2. Unplug any electrical devices from the receptacles.
3. Turn the fuel switch to the on "ON" position.
4. Turn the AC circuit breakers to the off "OFF" position (ignore this operation step if
equipped with one button start system)
5. If the engine is cold, pull out the choke knob.
6. Turn the generator switch to the start position "
engine starts.
NOTE: Do not hold the generator switch in the start position "
Holding the generator switch in the start position"
the starter. If the engine fails to start, wait 10 seconds before trying again.
7. After starting the engine, immediately release the generator switch so the switch
can automatically return to the on "ON" position.
7. After the engine has warmed, push the choke knob in.(ignore this operation step if
equipped with one button start system)
8. Turn the AC circuit breaker to the on "ON" position.

STOPPING THE ENGINE

1.
Disconnect the generator / unplug all electrical devices.
2.
Turn the AC circuit breaker to the off "OFF"position .
3.
Turn the generator switch to the off "OFF" position.
4.
Turn the fuel switch to the off "OFF" position.
" and hold it there until the
" for more than 5 seconds will damage
-
10
-
" for more than 5 seconds.