• To connect the unit, avoid cables that are too long.
• Single-phase welding machines should be connected to a socket equipped with a grounding pin.
• Welding machines powered by 3-phase mains are delivered without a plug, you should obtain such
a plug on your own and have the installation performed by a qualified person.
CAUTION! The device may only be operated if connected to installation with a functional fuse.
5.3.2. Gas connection
•
Place the gas cylinders away from the object to be welded and secure them against falling.
The gas connection of the welding machine must be connected to the gas cylinder or to the gas
•
supply system with a suitable hose and a regulator with a gas flow control. Caution! It is not
allowed to use network regulators for gas cylinders and vice versa. Such interchange may result
in reducer damage and personal injury.
•
Economical use of gas prolongs the welding time.
6. Product overview
Front view
Rear view: