BATTERIES

RED light
C A U S E
S O L U T I O N
Problem: the lift does not travel in either direction and the Light on the remote
control shines red when the remote control is operated.
Cause: the batteries in the remote control are flat.
Solution: replace the batteries in the remote control.

POWER

40 sec.
C A U S E
S O L U T I O N
Problem: the lift beeps for 40 seconds and the display shows a "2".
Cause: the lift batteries are not recharging, possibly the plug is not in the socket.
Solution: put the plug in the socket.