Herunterladen Inhalt Inhalt Diese Seite drucken

Kärcher IVS 100/40 Originalbetriebsanleitung Seite 20

Vorschau ausblenden Andere Handbücher für IVS 100/40:
Inhaltsverzeichnis

Werbung

Type of protection
Voltage
Maximum allowed net impedance
Fuse
Characteristic of the fuse
Blower data
Power
Vacuum*
* with pressure limiting valve
Effective filter area
Air quantity
Length x width x height
Cable length
Protective class
Power cord: Order No.
Mains cable: Type:
Suction hose connection (C-DN/C-ID)
Nominal width of suction hose
Typical operating weight
Storage temperature
Filter area
Values determined to EN 60335-2-69
Sound pressure level L
Uncertainty K
pA
Hand-arm vibration value
Uncertainty K
20
pA
IVS LP
IVS 100/40 LP
0.400+j0.250
Ohm
16 A
B/C
4200 W
17,5 kPa
139 l/s
1202 x 686 x1465 mm
6.650-822.0
155 kg
75 dB(A)
– 9
EN
IVS 100/55 LP
IVS 100/75 LP
IPX4
400 V 3~50 Hz
0.156+j0.098
0.400+j0.250
Ohm
16 A
C
5500 W
24,0 kPa
2,0 m²
139 l/s
8,2 m
I
6.650-822.0
6.650-823.0
H07RN-F
5x2,5 mm²
DN70
DN40/50/70
158 kg
-10...+40 °C
2,2 m
2
77 dB(A)
2 db (A)
<2,5 m/s
2
0,2 m/s
2
Ohm
32 A
B/C
7500 W
29,0 kPa
156 l/s
180 kg
73 dB(A)