Herunterladen Inhalt Inhalt Diese Seite drucken

Programming Field 1: Select Battery Type; Programming Field 2: Modify Boost And Refresh Modes - Cristec YPOWER+ 12V/16A Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für YPOWER+ 12V/16A:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3.3.2 Programming Field 1: Select battery type

Configuration according to type of batteries 12V or 24V
Description of the battery
Setting
0
Classic sealed type bat
1
2
3
4
5
Wintering or standby sealed
6
7
Stabilized DC power supply
8
Lithium iron phosphate
9
(LiFePO4) with BMS ***
10
11
12
13
14
15
Some specific settings are possible – please consult us.
(*)
Voltage on + BAT1, + BAT2, + BAT3 and + BATE, with 10% of the rated current and a tolerance of +/- 1%.
**
REFRESH is not advised for certain types of AGM batteries
(
)
(***)
Battery Management System
3.3.3

Programming Field 2: Modify BOOST and REFRESH modes

-
The BOOST function allows a faster charging of the batteries. This function is time controlled (see section 3.3.2):
BOOST mode to Float mode (see 3.4.8) for a battery current <20% of the nominal current of the charger (12%
in the case of the Lithium curve Iron Phosphate with BMS).
-
The REFRESH function allows to apply a voltage step periodically to maintain the battery, to promote its equalization
and thus prevent possible sulphating.
type
Opened type bat
free electrolyte (wet)
(Sealed Lead)
GEL type bat
AGM type bat**
Spiral type bat
Tin calcium lead bat
bat
SPE1 open type bat
STORMLINE Bat
Specific
Specific
---
---
---
Setting
0
1
2
3
FLOATING
BOOST
voltage *
voltage *
12V/24V
12V/24V
13.4V/26.8V
14.1V/28.2V
13.8V/27.6V
14.4V/28.8V
Factory setting
13.8V/27.6V
14.4V/28.8V
13.6V/27.2V
14.4V/28.8V
13.6V/27.2V
14.4V/28.8V
14.4V/28.8V
15.1V/30.2V
13.4V/26.8V
13.4V/26.8V
12.0V/24.0V
12.0V/24.0V
13.2V/26.4V
14.8V/29.6V
13.8V/27.6V
14.4V/28.8V
13.7V/27.4V
14.5V/29V
12.0V/24.0V
12.0V/24.0V
12.0V/24.0V
12.0V/24.0V
Customizable with Bluetooth
Customizable with CAN-Bus
REFRESH Mode
OFF
OFF
Factory setting
ON
ON
Maximum
duration of
BOOST at
+/- 5% T
BOOST
2H
2H
2H
2H
2H
2H
0H
0H
2H
6H
2H
0H
0H
Unused
BOOST mode
OFF
ON
OFF
ON
Maximum
duration of
ABSOPTION at
+/- 5% T
ABS
4H
4H
4H
4H
4H
4H
0H
0H
4H
1H
6H
0H
0H
44

Werbung

Inhaltsverzeichnis
loading