before the opening of the door only there may be only ember bed in the
burning space, i.e. no flames may be visible.
13. In heating mode, the surfaces, inspection glasses and handles may become
very hot. Warn children of these threats, and keep them away from the fire-
place when heated.
14. Ensure that the ashtray should be fully inserted, and in particular never re-
move hot ash from the fireplace (fire risk).
15. In transitional periods, chimney draught may drop, resulting in the imperfect
suction of the generated flue gases. In such cases, the fireplace is to be
filled with smaller quantities of fuel, preferably wooden chips or wood wool,
and it is to be commissioned under control with the stabilization of the chim-
ney draught. The fire grate should always be kept clean.
16. After the heating season, it is recommended to have the equipment in-
spected by an expert. It is also advisable to clean the routes of flue gases
and pipes.
17. Should repairs or reconditioning be needed, please, contact your dealer in a
timely manner with the accurate specification of the article and serial num-
ber. Only original Wamsler parts may be used.
18. As the air needed for burning is drawn from the room where the fireplace is
located, ensure that sufficient air supply is received via the gaps by the win-
dows and external doors. Make sure that 4 m
each kW of rated performance. For this fireplace, it means that the room has
to be at least 20 m in volume. If the room is smaller, sufficient air supply can
be secured by opening air connections to other rooms with air openings (at
least 150 cm
19. Ensure to keep proper lateral and rear distances from combustible parts and
materials. The associated values are specified in these user instructions or
the model plate.
20. The fireplace may not be modified.
21. The connection of the fireplace to the chimney is not permissible if the effec-
tive height of the chimney is less than 4 m, or 5 m with multiple loading. To
the chimney that the fireplace uses, a maximum of two other fireplaces, ov-
ens may be connected.
22. In the event of any chimney fire, immediately close all the openings of the
equipment, and call the fire service. Never try to extinguish the fire with wa-
ter. Thereafter, always have the chimney inspected by an expert.
2
).
3
of air should be provided to
23