AIR PANEL P-AP56NAMS
-
Hot air from a heater, etc. affects directly to the motion
sensor kit.
Blower device such as ceiling fan or ventilating fan
-
affects the airflow from the indoor unit.
Ambient temperature changes drastically.
-
Excessive force or vibration is applied to the motion
-
sensor kit.
Fluid or corrosive gas exists on the installing site.
-
Continuous use of the indoor unit in a high humidity
-
environment.
Weather affects directly to the surface of the motion
-
sensor.
-
Static electricity or electromagnetic wave is generated on
the installing area.
Moving object with temperature different from
-
surrounding.
Pay attention that the detecting function is decreased if the lens
for sensor smudges.
In this case, wipe off smudges by a cotton swab soaked alcohol
(Isopropyl alcohol is recommended.) or a soft cloth.
(When wiping off smudges on the lens for sensor, do not apply
excessive force. If excessive force is applied, the resin lens
may be damaged so that may cause malfunctions such as
misdetection or undetectable of the motion.)
!
C A U T I O N
Perform securely the installation work referring to this installation
manual. If the installation is not completed, it may cause injury by
falling down the motion sensor kit.
Do not install the motion sensor kit where the flammable gases may
generate or enter.
Turn OFF the power source completely before performing the
installation work and the electrical wiring work for motion sensor kit.
If not, it may cause an electric shock.
Do not apply excessive force to remove the corner pocket cover.
Otherwise, it may cause of deformation or damage of the plastic
hook, or may result injury.
Hold the air panel securely by hands to prevent it from falling when
it is removed.
Perform securely the electrical wiring work. If the electrical work is
not completed, heat generation at the connection, a fire or an electric
shock may occur.
Make sure that the electrical wires are securely fixed in order not to
apply an external force to the terminal connections of the wirings. If
fixing is not completed, it may cause heat generation or a fire.
!
C A U T I O N
Pay attention to perform the installation work at high-place using a
stepladder, etc.
?
N O T E
Do not move the louvre by hand.
If moved, the louvre mechanism will be damaged.
In addition, do not apply an excessive force to the air outlet part to
prevent the breakage.
10
PMML0570 rev.0 - 01/2021
1 The suspension height of the indoor unit should be referred
to "Installation & Maintenance Manual" of the indoor unit.
2 Do not touch the louvre during the installation work.
3 Remove the air inlet grille from the air panel.
While pushing both ends of knobs at the air inlet grille
toward the arrow direction, open the air inlet grille until the
angle of approximately 45° from the air panel surface. After
lifting the air inlet grille keeping it inclined, draw the air inlet
grille forward.
(Remove the filament tape (4 portions) fixing the air filter.)
Air inlet grille
Corner pocket
cover (4 portions)
?
N O T E
Although the air inlet grille can be opened until the angle of 90° from the
air panel surface, it can not be removed from the air panel.
4 Remove the corner pocket covers.
The corner pocket covers can be removed pulling Ⓐ part
toward the arrow direction in the figure below.
5 Check to ensure that the distance between the indoor unit
undersurface and the false ceiling undersurface is 16
as shown in the figure below.
False ceiling
Air panel
Knob
A
+3
mm
0
Indoor unit