Gaskets worn
Replace the gaskets
E
XCESS TROLLEY CLEARANCE
Contact technical service to adjust the
sliding blocks
L
OSS OF POWER IN TURNTABLE ROTATION
Loose belt
M
OTOR STOPS DURING USE
Overload cut motor protector activated
Open the electric system box, then
reactivate the overload cut motor
protector by turning the grey bar (A,
system box.
T
HE MACHINE DOES NOT MOVE
Current does not arrive to the solenoid
valve
Check the electric connection to the
solenoid valve
Solenoid valve blocked
Clean or replace the solenoid valve
Transformer fuse broken
Replace the fuse
Batteries run down (yellow LED on) (only in the radio versions)
Charge the batteries
Call the service centre
Pump broken
Replace the pump
Worn connection joint
Replace the joint
Not enough oil
Top up the oil
Defective switch
Replace the switch
When turning on the cold machine, quick translation does not work well.
heat up the oil for a few minutes by moving the machine at a normal speed.
78
N
O HYDRAULIC PRESSURE
E
XCESSIVE CONTROL UNIT NOISE
J
ERKY MOVEMENTS
A
- E
NGLISH