Herunterladen Inhalt Inhalt Diese Seite drucken

Transport; Disposal And Recycling; Troubleshooting; Possible Cause - Parkside PSKO 2410 A1 Bedienungs- Und Sicherheitshinweise

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

  • DEUTSCH, seite 1
11.6.1 Releasing excess pressure
Release the excess pressure by switching off the compressor
and using the compressed air which is still left in the pressure
vessel (8), e. g. with a compressed air tool running in idle mode
or with a blow-out pistol.

12. Transport

Use the transport handle (1) to transport the device, and drive
the compressor with it.
When lifting the compressor, note its weight (see Technical
data).
Ensure that the load is well secured when transporting the com-
pressor in a motor vehicle.

13. Disposal and recycling

Notes for packaging
The packaging materials are recy-
clable. Please dispose of packag-
ing in an  environmentally friendly
manner.
Notes on the electrical and electronic equipment
act [ElektroG]
Waste electrical and electronic equip-
ment does not belong in household
waste, but must be collected and dis-
posed of separately!
• Old batteries or rechargeable batteries that are not perma-
nently installed in the old unit must be removed before hand-
ing them in! Their disposal is regulated by the battery act.

14. Troubleshooting

Fault

Possible cause

The compressor does
Mains voltage is not available.
not start.
Mains voltage is too low.
Outside temperature is too low.
Motor is overheated.
The compressor starts but
The safety valve leaks.
there is no pressure.
The seals are damaged.
The drain screw for condensate leaks.
The compressor starts,
The hose connections have a leak.
pressure is shown on the
pressure gauge, but the
A quick coupling has a leak.
tools do not start.
Insufficient pressure set on the pressure regulator.
• Owners or users of electrical and electronic devices are le-
gally obliged to return them after use.
• The end user is responsible for deleting their personal data
from the old device being disposed of!
• The symbol of the crossed-out dustbin means that waste
electrical and electronic equipment must not be disposed of
with household waste.
• Waste electrical and electronic equipment can be handed
in free of charge at the following places:
- Public disposal or collection points (e.g. municipal works
yards)
- LIDL offers you return options directly in the branches and
stores. Return and disposal are free of charge for you.
- Up to three waste electrical devices per type of device,
with an edge length of no more than 25 centimetres, can
be returned free of charge to the manufacturer without
prior purchase of a new device from the manufacturer
or taken to another authorised collection point in your
vicinity.
- Further supplementary take-back conditions of the manu-
facturers and distributors can be obtained from the re-
spective customer service.
• If the manufacturer delivers a new electrical appliance to
a private household, the manufacturer can arrange for the
free collection of the old electrical appliance upon request
from the end user. Please contact the manufacturer's cus-
tomer service for this.
• These statements only apply to devices installed and sold in
the countries of the European Union and which are subject
to the European Directive 2012/19/EU. In countries outside
the European Union, different regulations may apply to the
disposal of waste electrical and electronic equipment.
Remedy
Check the cable, mains plug, fuse and socket.
Make sure that the extension cable is not too long. Use an
extension cable with large enough wires.
Never operate with an outside temperature of below +5 °C.
Allow the motor to cool down. If necessary, remedy the
cause of the overheating.
Contact your local service centre. Only allow qualified
personnel to carry out repairs.
Check the seals and have any damaged seals replaced by
a service centre.
Tighten the screw by hand. Check the seal on the screw
and replace if necessary.
Check the compressed air hose and tools and replace if
necessary.
Contact your local service centre. Only allow qualified
personnel to carry out repairs.
Increase the set pressure with the pressure regulator.
GB