control the flow rate through the heat pump).
To limit heat loss from the pipes, bury them underground (at a depth of 50 to 80 cm depending on the
region) or lag the pipes. In any case, minimize the amount of uninsulated pipe exposed to the air.
V.5) Wiring
The machine must be wired in by a qualified professional, after the hydraulic connections have been
completed. When dismantling the machine, disconnect it electrically before disconnected the hydraulic
connections.The heat pump's power cable connection terminal is located behind the socket. Use a cable with a
wirecross section that complies with the specification below, connected upstream to a breaking device rated
as set out in this table.
Thermal magnetic
circuit breaker rating(A)
Residual current device
Power cable (wirecross
section in mm2)
Remote installedcontrol
panel cable(wire cross
section inmm2)
*For a cable length less than 10 m. Increase the wire cross section if the cable is more than 10 m long. The cable
length should never exceed 50 m.
!
IMPORTANT :
Damaged cables must be replaced immediately by a qualified professional.
When installing the device, make sure earth wiring will present an ohmic resistance level complying with local
regulation requirements.
Check the electrical connections at the various terminals annually, tighten if necessary.
The heat pump's electrical and electronic components are not guaranteed against overvoltages produced by
lightning strikes. The electrical supply in the home must be adequately protected against this risk.
HI-HC
HI-HC
HI-HC
66
85
106
9.0
10.5
12.0
3 x 1,5
3 x 2,5
3 x 2,5
①Unscrew the 2 screws from the base of the panel on the
right hand side and remove the bottom section
of the panel.
②Remove the 3 screws from the lid of the electricalbox.
③Connect the power cable according to the standardised
markings (NB: in 3ph installations, live wires are marked
R,S,T / in 1 phinstallations, the live wire is marked L).
HI-HC
HI-HC
HI-HC
132
150
177
14.5
16.5
18.0
bipolar
sensitivity 30 mA max
bipolar
3 x 2,5
3 x 2,5
3 x 4,0
3 x 0.5
HI-HC
HI-HC
204
273
21.0
24.0
3 x 4,0
3 x 6,0
5 x 2,5
2019/11– C - Code : 33315
HI-HC
HI-HC
270
358
9.0
12.0
tetrapolar
trtrapolar
5 x 2,5
32 /76