Herunterladen Inhalt Inhalt Diese Seite drucken

Design And Function; Functional Description - WIKA RLT-1000 Betriebsanleitung

Reed-ketten-füllstandssensor
Vorschau ausblenden Andere Handbücher für RLT-1000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2. Design and function

Bullet
Instruction
1. ... x.
Follow the instruction step by step
Result of an instruction
See ... cross-references
2. Design and function

2.1 Functional description

Level sensors work on the float principle with magnetic transmission.
A permanent magnet built into the float  triggers, with its magnetic
field, the resistance measuring chain built into the guide tube . The
entire assembly corresponds to a 3-wire potentiometer circuit. The float
 changes its height with the level of the medium it is monitoring. The
measured resistance signal is proportional to the level. The measure-
ment voltage is very finely stepped due to the contact separation of the
resistance measuring chain and is thus virtually continuous.
WIKA operating instructions models RLT
≤ 30°
Connection housing
Cable gland
Spanner flats for screwing in
Sealing
Guide tube
Float
Float limitation
EN
5

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Rlt-2000Rlt-3000

Inhaltsverzeichnis