Herunterladen Inhalt Inhalt Diese Seite drucken

WIKA RLT-1000 Betriebsanleitung Seite 19

Reed-ketten-füllstandssensor
Vorschau ausblenden Andere Handbücher für RLT-1000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9. Specifications
Model RLT-2000
Specifications
Output signal
Accuracy, resolution
Operating conditions
Medium temperature
limit
Ambient temperature
limit
Storage temperature
limit
WIKA operating instructions models RLT
Variable resistance
The overall resistance of the reed chain is approx.
1 ... 10 kΩ, depending on the measuring range
Max. voltage < DC 40 V
Current output, 2-wire
Auxiliary power: DC 12 ... 32 V
Load in Ω: ≤ (auxiliary power - 12 V) / 0.02 A
Voltage output, 3-wire
Auxiliary power: DC 12 ... 32 V
Load: > maximum output signal / 1 mA
24 mm [0.94 in]
20 mm [0.79 in]
12 mm [0.47 in]
10 mm [0.39 in]
6 mm [0.24 in]
3 mm [0.12 in]
PP: -10 ... +80 °C [14 ... 176 °F]
PVDF (option): -10 ... +80 °C [14 ... 176 °F]
Option: -30 ... +120 °C [-22 ... +248 °F]
PP: -10 ... +80 °C [14 ... 176 °F]
PVDF (option): -30 ... +80 °C [-22 ... +176 °F]
PP: -10 ... +80 °C [14 ... 176 °F]
PVDF (option): -30 ... +80 °C [-22 ... +176 °F]
EN
19

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Rlt-2000Rlt-3000

Inhaltsverzeichnis