conditions, in accordance with the installation rules. •The
product features a special power cable; if the cable is
damaged, contact the Service Centre for a replacement.
● Please note! Before reconnecting the circuit to the
mains power supply, make sure that it is working correctly,
always check that the power cable is correctly installed.
Please note! Do not use with a programmer, timer,
separate remote control or any other device that activates
automatically.
The product can also be used in
WINDOWS KIT:
conjunction with a Window sensor KIT (not supplied by
the manufacturer). If the Window sensor KIT is installed
(only if used in DUCT-OUT mode), air extraction will halt
every time the window in the room, on which the KIT is
applied, is closed. The KIT must be electrically
connected to the device by qualified and specialised
technical personnel. The KIT must be certified
separately in accordance with the safety standards for
the component and its use with the device. Installation
must be carried out in accordance with current
regulations for domestic systems.
PLEASE NOTE: the wiring of the KIT to be connected
to the product must be part of a certified safety extra-
low voltage (SELV) circuit. The manufacturer of this
device disclaims all liability for any inconvenience,
damage or fires caused by defects and/or problems
associated with the malfunction and/or incorrect
installation of the KIT.

RECOMMENDATIONS FOR USE

Recommendations for correct use in order to reduce the
impact on the environment: When cooking begins, the
device should be turned on at minimum speed, and left on
for a few minutes even after cooking is complete. Increase
the speed only if there is a large quantity of fumes and
steam, using the Booster function only in extreme cases.
To keep the odour reduction system running efficiently,
replace the carbon filter/s when necessary. To ensure the
high performance of the grease filter, clean it when
necessary. To improve efficiency and minimise noise, use
the maximum duct diameter indicated in this manual.

END-OF-LIFE DISPOSAL

This device is marked in compliance with the Eu-
ropean Directive 2012/19/EC - UK SI 2013
No.3113, Waste Electrical and Electronic Equip-
ment (WEEE). Make sure that this product is di-
sposed of correctly. The user helps prevent po-
tential negative consequences for the environ-
ment and for health.
The
symbol
on
the
documentation indicates that this product should not be
treated as household waste but should be handed over at a
suitable collection point for the recycling of electrical and
electronic equipment. Dispose of it in accordance with local
regulations for waste disposal. For further information
about the treatment, recovery and recycling of this product,
please contact your local authority, the collection service
product
or
accompanying
for household waste or the shop from where the product
was purchased.
REGULATIONS
Equipment designed, tested and manufactured in
compliance with safety regulations: EN/IEC 60335-1; EN/
IEC 60335-2- 31, EN/IEC 62233. Performance: EN/IEC
61591; ISO 5167-1; ISO 5167-3; ISO 5168; EN/IEC
60704-1; EN/IEC 60704-2-13;EN/IEC 60704-3; ISO 3741;
EN 50564; IEC 62301. EMC: EN 55014-1; CISPR 14-1; EN
55014-2; CISPR 14-2; EN/IEC 61000-3-2; EN/IEC
61000-3-3.
USE
The hood is made to be used in the suction version with
external evacuation.
It is possible to purchase a Kit for the recirculating version
(see the next paragraph
ATTENTION!: The pipes are not supplied and must be
purchased separately.
Duct-Out Version:
The use of pipes and outlet holes in the wall with a smaller
diameter will reduce the extraction performance and
drastically increase the noise level.
All responsibility in this regard is therefore denied.
• Use a ducting pipe with the shortest length necessary.
• Use a ducting pipe with the least number of bends
possible (maximum bend angle: 90°).
• Avoid drastic changes in the ducting pipe diameter.
Recirculating Version:
The suctioned air will be degreased and deodorised before
it is sent back into the room. To use the product in this
version, it is necessary to install an additional activated
carbon filter system.
ASSEMBLY BEFORE INSTALLATION
• Check that the product is the right size for the installation
area.
• Remove the activated carbon filter(s) if supplied (see also
relevant paragraph).
• It(they) must be reinstalled if the product is used in the
filter version.
• If there are panels and/or walls and/or wall units on the
sides, make sure that there is enough space to install the
product and that it is always possible to access the control
panel easily.
• The product is equipped with fixing plugs suitable for most
walls/ceilings. However, it is necessary to consult a
qualified technician to make sure that the materials are
suitable for the type of wall/ceiling. The wall/ceiling must be
strong enough to support the weight of the hood.