Our appliances are compatible with various load shedding systems. However, you must not use
mains shut-off load shedding, since these systems are incompatible with our appliances. Sudden,
inadvertent and repeated power shut-offs can cause premature wear and damage to the electronics
boards, which would not be covered by the manufacturer's warranty.
During load shedding periods, the screen displays Of and FP.
The appliance will then return to its initial operation.
A
CCESSING THE ADVANCED FUNCTIONS
at the same time for at
least 3 seconds
Then press and hold these two buttons at the same
time for more than 3 seconds.
There may be a difference between the setpoint temperature, and the temperature actually
measured in the room. This is generally due to the appliance installation conditions (location,
power/volume, room insulation, etc.). Calibration is used to adapt the thermostat setting to the
actual room conditions.
1 - Switch the appliance to Comfort mode at 20 °C, and wait for a few hours.
2 - Measure the room temperature using a thermometer and calculate the difference (measured
temperature - setpoint temperature).
3 - Press and hold the

(Calibration).

4 - Press
,
5 - Set the new value using the
6 - Press
to exit.
Example: After several hours in Comfort mode with the temperature set to 20 °C,
I measure a room temperature of 18 °C. So, I set a difference of 18- 20=-2.
Example: After several hours in Comfort mode with the temperature set to 20 °C, I measure a
room temperature of 22 °C. So, I set a difference of 22- 20=+2.

Load shedding

Advanced functions

Press any button to activate the display.
CALIBRATION
and
buttons at the same time for more than 3 seconds to display
will flash alternately with the currently set difference
buttons (between -3 °C and +3 °C).