Herunterladen Inhalt Inhalt Diese Seite drucken

Anomalies And Solutions - Atag ENERGION Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Service

Anomalies and solutions

In case of problems, run the following checks before contacting a Technical Assistance Service.
Anomalies
Unsatisfactory cooling performances
The unit does not work
The unit starts or stops frequently
Unsatisfactory heating performances
NOTE: if, after performing the checks and diagnostics procedures described above, the problem persists, switch the unit off
immediately and contact a Technical Assistance Service.
Possible causes
The set temperature could be higher
than the room temperature
The heat exchanger of the indoor or
outdoor unit is dirty
The air inlet or outlet of the outdoor
unit is obstructed
Door and windows open
Sunlight generates excessive heat
Too many sources of heat in the room
(people, computers, electronic devices,
etc.)
Low refrigerant level due to leakages or
extended use
Power shortage
The unit is switched off
The fuse has blown
The timer is active
There is too much or too little refriger-
ant in the system
Incompressible gas or humidity has
entered the system.
The compressor is faulty
The voltage is too high or too low
The outdoor temperature is extremely
low
Cold air seeps in from doors and win-
dows
Low refrigerant level due to leakages or
extended use
Solutions
Set a lower temperature
Clean the heat exchanger (Service
Centre)
Switch the unit off, eliminate the cause
of the obstruction and switch the air
conditioner on again
Close the doors and windows while
using the unit
Draw the curtains and close the
windows during the hottest hours of
the day or when the sunlight is more
intense
Reduce the sources of heat
Check that there are no leakages, reseal
the system if necessary and top up the
refrigerant (Service Centre)
Wait for electricity to be restored
Switch the appliance on
Replace the fuse (Service Centre)
Deactivate the timer
Check that there are no leakages and
top up the refrigerant if necessary
(Service Centre)
Purge the system and recharge the
refrigerant (Service Centre)
Replace the compressor (Service
Centre)
Install a voltage regulator (Service
Centre)
Use an auxiliary heating appliance
Close the doors and windows while
using the unit
Check that there are no leakages, reseal
the system if necessary and top up the
refrigerant (Service Centre)
75 / EN