User Menu
PHOTOVOLTAIC INTEGRATION
This menu is available for products that are configured for
integration with a photovoltaic system (heating/cooling, hy-
brid, DHW heat pumps).
– "Photovoltaic integration": sets the use of the DHW
storage tank heating element for supported heat pumps
(see the product manual for further information).
– "None"
– "Photovoltaic integration": activates the heating
element of the DHW storage tank (also simulta-
neously to heating or cooling) when additional
electrical energy is available from the photovoltaic
system.
– "PV offset DHW setpoint temperature": if a heating
heat pump or a hybrid system is installed, the parameter
sets the degrees to be added to the temperature set-point
for DHW storage tank charge when additional electrical
energy is available from the photovoltaic system.
– "PV setpoint temperature": if a DHW heat pump is in-
stalled, the parameter sets the temperature set-point for
DHW storage tank charge when additional electrical ener-
gy is available from the photovoltaic system.
SYSTEM MEASUREMENT UNIT
This parameter sets the unit of measurement (international
system or USA system)
Advanced settings
Cooling settings
AUTO function
System measurement unit
Time Program mode
Room temperature correction
Zones selection
International system
USA system
Fig. 69
TIME PROGRAM SERVICE TYPE SET
Sets the time schedule mode used by the device for heating
and cooling.
– "Two levels setpoint": the daily 2-level time schedul-
ing allows for dividing the schedule into a maximum of
4 comfort slots and 4 reduced-temperature slots within
the 24 hours of each day. It is possible to define a tem-
perature set-point for the comfort slot and one for the re-
duced-temperature slot.
– "Multilevel setpoint": in daily multi-level time schedul-
ing, available only on specially configured products, it is
possible to define up to 12 daily slots, each of which can be
associated with a specific set-point temperature.
Advanced settings
Cooling settings
AUTO function
System measurement unit
Time Program mode
Room temperature correction
Zones selection
Two levels setpoint
Multilevel setpoint
Fig. 70