52
6 .
O P E R A T I O N
6 . 1 .
S p e c i a l o p e r a t i o n a l s a f e t y i n s t r u c t i o n s
CAUTION
Start-up and operation of unit shall only be performed by
qualified personnel!
6 . 2 .
C o n t r o l s a n d i n d i c a t o r s
4
11
C O N T R O L S
Description
1
Output current setting: 10 turn
[0 ≡ 0A ; 10 ≡ Max. output current]
2
Output voltage setting: 10 turn
[0 ≡ 0V ; 10 ≡ Max. output voltage]
3
Pole reversal switch: (option 60)
The output polarity switches from + to – or vice versa
4
Power switch: Power ON => Switch lights up green
5
HV button: Enabling/disabling the output voltage
6
Ext. / int. switch: Ext. : Current/voltage setting via the
interconnected analogue interface. Int. : Current/voltage setting via
the internal potentiometer (1 or 2)
I N D I C A T O R S
Description
7
Output current (in mA)
8
Output voltage (in V)
9
Constant current mode: ON => LED lights up yellow
10
Constant voltage mode: ON => LED lights up yellow
5
HV button: HV ON => Button lights up red
11
Control / Digital see 7.2.17 Option 72 / 76: Digital interface (12- or
16-bit) on page 63
7
8
6
9
1
2
10
5
3