OPERATING DIAGNOSTICS

The indicator lights on the front of the Rollixo receiver notify the user of the installation's status.
Indicator light status Meaning
Off
Permanently lit Installation fault/failure
Indicator light status
Motor
Radio safety
edge
Photoelectric
cells
If a fault is still present on your installation, please contact your installer.
6
Functional installation
Deactivation/activation in
progress
Diagnostics
Prog
Activated
motor thermal
protection
Radio
interference on
the safety edge
transmitter
Safety edge
transmitter
low battery
indication.
Obstacle
detection
Cell fault
Obstacle
detection
Motor
Fall protection
Safety edge
1
STOP
Consequences Actions/Troubleshooting
No movement
possible
Opening and
stopping ok
Closed by
pressing and
holding down
Opening ok
Closed by
pressing and
holding down
Remove the
obstacle by
automatic
partial opening
Opening ok
Closed by
pressing and
holding down
Remove the
obstacle by
full automatic
opening
Copyright © 2012 Somfy SAS. All rights reserved
Safety edge
transmitter batteries
Photoelectric cells
2
3
4
Prog
Wait around 10 minutes.
If a powerful radio system
is present on the site
(infrared detector, TV
transmitter, etc.) and is
transmitting on the same
frequency, the receiver will
wait for the transmission
to end to before controlling
the door again.
If the fault persists, replace
the safety edge transmitter
batteries.
Check that no obstacle is
causing the safety edge to
detect.
Check that no obstacle
is cutting across the cell
beam
Check that no obstacle
is cutting across the cell
beam.