200 HT - 260 HT
With ECO mode selected, the heat pump will operate until the
set-point is reached and the heating element is switched on until
the photovoltaic set-point set from the installer menu is reached.
Otherwise, with AUTOMATIC mode selected, the heating ele-
ment can also be switched on before reaching the set-point of
this mode if the conditions require it.
7.5.9 Off-Peak Mode
When the photovoltaic mode is activated from the installer
menu, only ECO - AUTOMATIC will be available.
When the symbol
on the display flashes, the Off-Peak
mode is not operating and the unit remains on standby and the
heat pump and heating element are off.
Otherwise, when the symbol
works in the ECO or AUTOMATIC mode.

7.6 Additional functions

7.6.1 Anti-Legionella
The display shows the symbol
Every two weeks, at the set time, a water heating cycle is car-
ried out by means of the heating element inside the tank, up to
the anti-legionella temperature, maintaining it for the set time.
If, on reaching the anti-legionella temperature, the cycle is not
performed correctly within 10 hours, it is stopped and will be run
again after 2 weeks.
If the request for the anti-legionella function occurs with HOLI-
DAY mode selected, the anti-legionella cycle will be carried out
immediately when the unit is reactivated after the set days of
absence.
Anti-legionella parameters
Anti-legionella temperature set-point (P3)
Anti-legionella cycle duration (P4)
Anti-legionella cycle activation time (P29)

7.6.2 Defrost function

The display shows the symbol
This equipment has an automatic evaporator defrost function
which is activated, when the operating conditions require it, dur-
ing heat pump operation.
Defrosting occurs through the injection of hot gas into the evap-
orator, allowing it to be rapidly defrosted.
During defrosting, the heating element, which the equipment is
provided with, is switched off unless otherwise set via the install-
er menu (parameter P6).
The max. duration of defrosting is 8 minutes, unless otherwise
specified.
+
or
+
+
on the display is lit up, the unit
.
Range
50÷75°C
0÷90 min
0÷23 h
.

7.6.2.1 Frost protection

The display shows the symbol
This protection prevents the water temperature inside the tank
from reaching values close to zero.
With the equipment in standby mode, when the water tempera-
ture inside the tank is below or equal to 5°C (parameter config-
urable via installer menu), the frost protection function activates,
which switches on the heating element until 12°C is reached
(parameter configurable via installer menu).

7.7 Control of equipment via APP

This water heater has a Wi-Fi module integrated in the product,
enabling connection to an external Wi-Fi router (not supplied)
and therefore being controlled via smartphone APP.
Depending on the availability of a smartphone with Android
iOS
operating system, via the dedicated app.
®
Download and install the "EGEA Smart" app
Start the "EGEA Smart" app from your smartphone by pressing
the icon as indicated above.

User registration

To use the "EGEA Smart" application for the first time, user
Default
registration is required: create a new account → enter the mo-
75°C
bile number/email address → enter the verification code and set
30 min
the password → confirm.
23 h