Herunterladen Inhalt Inhalt Diese Seite drucken

Operation - BWT ECOSOFT ROBUST 1000 Installation Und Betriebsanleitung

Umkehrosmose-systeme
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 102
INSTALLATION AND OPERATION GUIDELINES FOR REVERSE OSMOSIS SYSTEMS ECOSOFT ROBUST1500 ECO,
ROBUST MINI ROBUST 1000, ROBUST 1500 / 1500 ЕС, ROBUST PRO / PRO EC, ROBUST 3000 / 3000 EC

6. OPERATION

RObust reverse osmosis system should be used for purification of cold water only.
Monitoring of the system is carried out based on the readings of pressure gauges* and evaluation
of production.
Pressure after pre–filters (left pressure gauge). If pressure after pre–filters is less than 1 bar, this
may indicate low mains pressure or clogged pre–filters. Test pressure at the feed adapter site. If it
exceeds reading on the pressure gauge significantly, replace pre–filters. Otherwise, low feed water
pressure is at fault and has to be sorted out. If the 1st pressure gauge displays over 5 bar after the
system switches on, power down the system immediately, disconnect water supply, and install a
pressure regulator upstream of the system. Then, continue setting up the system. Recommended
feed water pressure is 3,5 bar.
Operating pressure (right pressure gauge). If operating pressure in the membrane is lower than
4 bar or falls to the value of the feed water pressure, this can be caused by the following:
• motor power supply fault (possibly due to broken/torn pump motor cord);
• air trapped inside pump's chamber;
• jamming of the pump with solids such as carbon fines (if carbon filter was not properly rinse
before use).
Generally, if operating pressure reading on the 2nd pressure gauge falls below its normal range,
contact your dealer's service. If pressure on 2nd pressure gauge is over 7 bar, this could be due
to pressure regulator failure or the RO system's high pressure switch fault. Contact your dealer's
service for help.
Performance. Reduced system flow rate is a sign of exhausted capacity of pre-filters. Untimely
replacement of them leads to contamination of membranes and complete loss of their productivity.
With a significant drop in system performance, replacement of reverse osmosis membranes is
required.
In the event of long breaks in the system operation (more than 2 weeks), disinfect the system as
described in paragraph 7 and shut off the water supply to the system.
* There are no pressure gauges in the Robust Mini product, they need to be installed additionally to check the pressure in the system.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2021
Pressure
a�er cartridges
lower than 1 bar
Change
cartridges
higher than 5 bar
Install a pressure
regulator
Figure 6. Operating parameters of the system
Opera�ng
pressure
lower than 4 bar
Contact a�er
sale service
higher than 7 bar
Contact a�er
sale service
23

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis