8
Start rinsing pre–filters: open a special rinse valve and pass the required volume of water
to the bucket until there are no carbon fines in rinsewater.
9
Install all membranes in membrane housings.
CAUTION! When installing reverse osmotic
membrane, do not take it out of the bag. Cut the
bag at the opposite end to membrane's brine seal,
push the membrane inside membrane housing. Do
not touch membrane surface at any time.
10
Open feed valve and purified water faucet for 30 minutes to rinse membranes and other
parts of the system. Do not open tank valve at this time. Close the purified water faucet and
check all connections for leaks.
CAUTION! Inspect the system for leaks every day for the first week after installation.
Continue to check periodically onward. When leaving for an extended while, shut off
main valve to remove water supply to the system.
11
Insert the post-filter into housing and screw it. For RObustPro system insert special
RObustPro filter and post-filter into the housings and screw them.
Open the water supply and purified water faucet for 5-10 minutes to rinse the carbon filter.
12* Open tank valve and let the system fill it. Open purified water faucet and discard the first
tank of purified water. When the tank is drained empty, close the purified water faucet and
let the system refill the tank. The water can be used now.
13
Сontact your local dealer to connect RObust 1500 EC, RObust PRO EC and RObust 3000 EC to
the Internet and personal Econnect account.
* Skip steps 4 and 12 if installing a tankless system.

5. POST-INSTALLATION

1. Use calibrated TDS meter to test your tap water and purified water total dissolved solids.
2. Verify proper functioning of feed water solenoid. The system must switch off and stop discharging
concentrate when pressure tank is full* and purified water faucet is closed.
3. Inspect the system carefully for leaks.
4. Make a record of system installation in maintenance log paragraph 9.
5. *Operation with the pressure tank. When the tank is full, the pump is switched off and the drain stop.