9. Specifications
Options for specific media
Oil and grease free
Oxygen, oil and grease free
Process connections
Standard
DIN EN ISO 1179-2 (formerly DIN 3852-E)
EN 837
ANSI/ASME B1.20.1
ISO 7
KS
-
1) suitable for oxygen, oil and grease free.
WIKA operating instructions, pressure sensor, model A-1200
Residual hydrocarbon: < 1,000 mg/m ²
Residual hydrocarbon: < 200 mg/m²
Packaging: Protection cap on the process connection
Max. permissible temperature -20 ... +60 °C [-4 ... +140 °F]
Available measuring ranges:
0 ... 400 mbar to 0 ... 400 bar [0 ... 10 to 0 ... 5,000 psi]
-1 ... 0 to -1 ... 24 bar [-14.5 ... 0 to -14.5 ... 300 psi]
Factory supplied without sealing
Available process connections, see "Process connections"
Thread size
G ¼ A
G ½ A
1)
G ¼ B
1)
G ¼ female
1)
G ½ B
1)
¼ NPT
1)
½ NPT
1)
R ¼
1)
PT ¼
G ¼ female (Ermeto compatible)
Max. nominal pressure
600 bar [8,700 psi]
400 bar [5,800 psi]
1,000 bar [14,500 psi]
1,000 bar [14,500 psi]
1,000 bar [14,500 psi]
1,000 bar [14,500 psi]
1,000 bar [14,500 psi]
1,000 bar [14,500 psi]
1,000 bar [14,500 psi]
1,000 bar [14,500 psi]
EN