BVS ID-M1280_F1-L3- _ _ _
Identsensor
Startup (continued)
On delivery, the Identsensor is ready for operation.
The device's firmware is subject to continuous revi-
sion and increases the performance of the device.
The current firmware version is located on
www.balluff.com in the product download sec-
tion.
Besides the Identsensor, the following is required:
Power I/O cable (M12, 2 meters)
Type des.: BCC M41C-0000-1A-169-PS0C25-
020-C009 Order code: BCC0KE6
Power supply 24 V
18 ... 30 V LPS Class 2 / Type 1
LAN cable Gigabit Ethernet (as an option)
Type des.: BCC M418-E818-8X0-723-PS58N9-020
Order code: BCC0HZK
Requirements: at least category 5e in accordance with
EIA/TIA-568. Transfer in accordance with 1000BASET/
100BASE-TX/10BASE-T is being supported.
Establish a connection with the Identsensor
1. Connect the Identsensor via the LAN port with the
network (fixed IP address) or with a PC directly (LLA/
Zeroconf), or via IO-Link (using der Power I/O cable;
see 2.).
2. Connect the power supply at the Power port with the
power supply (24 V).
The Identsensor starts up and is operational after
approx. 100 seconds.
The Identsensor is shipped with the following fixed IP
address (LAN connection): 192.168.10.2 (Subnetzmaske
255.255.255.0). The network must be configured ac-
cordingly and port 80 should be enabled in the firewall
settings.
A direct LAN connection with a PC, which is set to "Obtain
an IP address automatically" initiates a LLA/Zeroconf-
connection. After approx. 5 minutes a connection to the
BVS ID is possible via:
http://xxxxxxxxxxxxxxxx.local (see part label)
Connecting the Identsensor via IO-Link with an accordingly
configured IO-Link Master, then the Identsensor is running
in IO-Link communication mode.
At the start, the Identsensor opens the most recently ope-
ned inspection and executes it.
Execute Auto Setup
1. Press on the Auto Setup button for at least 2 and to a
maximum of 4 seconds.
1
Auto Setup will start, one red target LED will light up.
www.balluff.com
Startup (continued)
2. Position the Identsensor using the red light beam to
3. Then fix the Identsensor.
4. Press the Auto Setup button to confirm the positioning
Adapt settings
With the web interface ("SensorApp") the Identsensor can
be adapted. This is
Perform the following steps:
1. Open a web browser.
2. Enter the following URL: http://192.168.10.2/.
3. Confirm the entry.
Reset network settings (optional)
You can reset the network settings of the Identsensor
temporarily to the shipment state (http://192.168.10.2/) the
following way until the next restart:
1 Auto Setup
Balluff GmbH
button
Schurwaldstrasse 9
73765 Neuhausen a.d.F.
Germany
Tel. + 49 7158 173-0
Fax +49 7158 5010
balluff@balluff.de
point to the target object which includes the code.
Please note the following:
The code on the target object must be within the per-
missible range of the Identsensor.
Only one code should be within the field of view of the
Identsensor during the Auto Setup process.
The target object with the code must not move during
the Auto Setup process.
of the Identsensor.
Now, the Identsensor automatically sets the brightness,
the focus, and the code type. The process will take ap-
prox. 2 minutes. In doing so, the Identsensor will flash
Startup (continued)
several times.
As soon as the Auto Setup process is finished, the
Identsensor will confirm this with a final flashing. For
this, there are the following flashing codes:
Light up for 3 seconds – Auto Setup was successful .
Six-times short flashing – Auto Setup failed.
mandatory if the Auto Setup process was not success-
ful,
optional, to check the automatically set parameters
and to optimize them manually after a successful Auto
Setup process, or
optional, to adapt network or communcation settings
manually.
Press on the Auto Setup button for approx.
15 seconds.
english
2