AFRISO EURO-INDEX Eurovac HV Betriebsanleitung Seite 154

Vakuum-leckanzeigegerat
Vorschau ausblenden Andere Handbücher für Eurovac HV:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Any malfunctions that cannot be removed by means of the measures
described in this chapter may only be repaired by the manufacturer.
Green LED is not on
Red LED is on
Yellow LED flashes
Water in condensate
trap
Filter polluted
Other malfunctions
No supply voltage
Flat cable not properly
connected to printed cir-
cuit board
Leak exists
Test/measurement
valve in position
"Test/Vent"
Condensate trap or
liquid barrier open
Annual maintenance
required
-
-
-
Apply supply voltage
Connect the flat cable to
the printed circuit board
in correct position
Check the hose lines
and hose connections
Notify a specialised
company
Set the test valve and
the measurement valve
to position "Normal
Operation"
Close the condensate
trap or the liquid barrier
Perform annual mainte-
nance (see chapter
"Maintenance")
Drain the condensate
trap
Replace the filter
Contact the AFRISO
service hotline
Eurovac HV
EN