Operating the product is limited to its regular monitoring:
The green LED is on.
The red LED is off.
The audible alarm is off.
In the case of a leak alarm, the red LED is permanently illuminated and the
audible alarm is activated. The relay is energised.
The alarm signal can be transmitted to additional equipment via the relay
output.
In the case of products with an EnOcean® wireless module, the product
sends a message to the AFRISOhome gateway. The user receives a
message from the AFRISO app that a leak has been detected.
1. Press the Acknowledge key to mute the audible alarm.
- The red LED remains lit.
2. Immediately notify a specialised company.
The specialised company remove the cause before the product is recommis-
sioned.
3. Have the function test performed by a specialised company.
No alarm is triggered in case of a power outage. When mains voltage is
restored, the product immediately resumes operation. If, during the power
outage, leakage has occurred, the product triggers an alarm once power is
available again.