Herunterladen Diese Seite drucken

AFRISO EURO-INDEX Eurovac HV Betriebsanleitung Seite 129

Vakuum-leckanzeigegerat
Vorschau ausblenden Andere Handbücher für Eurovac HV:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The product complies with:
EMC Directive (2014/30/EU)
Low Voltage Directive (2014/35/EU)
Construction Products Directive (EU) No. 305/2011 and No. 574/2014
RoHS Directive (2011/65/EU)
Weight
Emission/alarm sound
Additional connections
Breaking capacity output relay
Relay fuse
Operating pressure in interstitial space Approx. -400 mbar
Switching point Alarm On
Switching point Alarm Off
Switching point Pump On
Switching point Pump Off
Connecting hose
Ambient temperature operation
Ambient temperature outdoor installa-
tion with protective housing and heating
Ambient temperature storage
1.1 kg
Min. 70 dB(A)
A-weighted sound level of the
audible alarm at a distance of one
metre
1 output relay (voltage-free
changeover contact)
Max. 250 V, 2 A, resistive load
T 2 A
-340 ±10 mbar
-380 ±10 mbar
-380 ±10 mbar
-420 ±10 mbar
PVC hose 6 x 2 mm
-5 ... 60 °C
-25 ... 60 °C
-25 ... 60 °C
Eurovac HV
EN

Werbung

loading