Herunterladen Inhalt Inhalt Diese Seite drucken

Zibro P 24 Gebrauchsanweisung Seite 73

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
Water hole
Rubber plug
Drain knob
e
Air flOW
Move the air vent directly to adjust the air flow direction.
f
emPtY internAl WAter cOntAiner
Under extreme (environmental) circumstances it may be necessary to empty the
internal water container regularly. When the internal water container is full the
light will flash and the unit will beep continously. Touch any button to stop
the beeping. The unit will switch off automatically. To empty the water container
do the following:
1
Do not move the unit. Drastic movements can cause water leakage.
2
Switch off the unit and remove the plug from the wall outlet.
3
Place a pan or appropriate tray on the floor underneath the drain hole.
4
Remove the drain knob and rubber plug K from the drain tube and let the
water run out. (± 0.8 litres).
5
Replace the rubber plug K and the drain knob and switch on the unit. The
warning light
G
nOte!
When the air conditioner is in use, under normal circumstances the
condensed water will be drained through the air outlet-tube.
dehumidificAtiOn
If the unit will be used mainly as dehumidifier, do not connect the exhaust hose
and let the warm air return in the room. Continuous drainage is then necessary
and more efficient. You must, however, use a water drain tube, placing its
discharge end at a suitable drainage point.
g
cOnnectiOn tO A PermAnent drAin
1
First switch the device off and pull the plug out of the socket.
2
Place a pan or container on the ground under the water drain K in order to
catch any remnant water.
3
Remove the rubber plug from the water drain K.
4
Slide a water drain hose over the water drain K.
should be off.
4
73

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis