11 ALARM MANAGEMENT

If a malfunction occurs, the following procedure is activated:
1. audible alarm (beep);
2. one of the following system LEDs come on:
3. if the problem concerns an error, the stove will switch off.
Pressing and holding the "cancel" button
ERROR/
WARNING CODE
E001
E002
E004
E101
E105
E106
E108*
E108**
E109*
E109**
E110
E111
A001
A002
A007
----
----
* Only in the stoves equipped with micro safety-switches on the firebox door and on the pellet hopper lid.
** Only in the stoves without micro safety-switches on the firebox door and on the pellet hopper lid.
After having checked the type of message, the alarm can be reset by pressing the on/off
button
for a few moments.
If the error code is "E108 or E109", before resetting the alarm, manually reset the thermostat
located on the rear of the stove (Fig. 11.1). Then the stove can be started again.
DESCRIPTION
Faulty control panel
Remote control signal communication error Control panel fault
Communication error
Failed ignition error
Outlet water temperature too high
Temperature probe malfunction
Temperature probe malfunction
Safety error
Thermal safety
Incorrect pressure or thermal cutout
Pressure error
Temperature probe malfunction
Flue gas temperature probe malfunction
Low pellet level (icon flashing)
Scheduled maintenance warning (icons
flashing)
Pressure sensor malfunction (icon
flashing)
Clean stove
Failed ignition error
004772533 - 16/03/2021
;
shows the error code on the display:
POSSIBLE CAUSES
Control panel fault
Connection cable between board and control panel
interrupted or detached.
If this appears when changing configuration, ignore the
error
No pellets
Pellet quality
Faulty ignition system
Burn pot dirty
Problems with the heating system
Problems with the pump
Faulty return water temperature probe
Faulty buffer tank temperature probe
Door or loading hatch open
Problems with the heating system
Problems with the pump
Problems with overheating in the pellet hopper
Flue system dirty
Seals worn
Insufficient combustion air
Heating system malfunction
Circulation pump malfunction
Pellet tank overheating
Flue gas exhaust system dirty
Seal gaskets worn
Insufficient combustion air
Faulty outlet water temperature probe
Faulty air temperature probe
Faulty flue gas temperature probe
Pellets running out
The stove periodically requires maintenance to be
performed by a qualified technician
Pressure sensor or board fault.
Combustion chamber, burn pot or flue gas exhaust system
dirty.
Pressure measuring tubes detached or blocked.
Combustion air intake blocked.
No pellets; Faulty ignition heater; Worn gaskets; Incorrect
burn pot position
LED
Fig.11.1
57