Herunterladen Inhalt Inhalt Diese Seite drucken

Palazzetti ECOFIRE IDRO Anleitung Seite 43

Vorschau ausblenden Andere Handbücher für ECOFIRE IDRO:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 62
5.5.1 Discharge through roof using a traditional
chimney
The chimney used to discharge the flue gas must
be made in accordance with standards UNI 10683
- EN 1856-1-2 - EN 1857 - EN 1443 - EN 13384-
1-3 - EN 12391-1 both as regards the dimensions
and the construction materials used.
DAMAGED chimneys made from unsuitable
material (asbestos cement, galvanised steel,
etc.... with a rough and porous inside surface) are
prohibited by law and affect proper stove operation.
The flue gas can be discharged through a traditional
chimney (Fig. 5.8) as long as you make sure on the
state of maintenance of the chimney.
For larger chimneys, suitably insulated steel
pipes need to be inserted on the inside (diameter
according to the length) (Fig. 5.9).
Makes sure connections to brick chimneys are
suitably sealed.
If the flues run through wooden roofs or walls,
special certified pass-through kits need to be used,
available on the market.
1) Vermiculite and/or rock wool.
2) Steel pipes.
3) Closure panel.
A) Chimney pot with wind protection
B) Seal
C) Inspection
004772533 - 16/03/2021
Fig. 5.8
1
2
3
Fig. 5.9
43

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis