6 INSTALLATION
The stove must be installed by qualified personnel in compliance with EN 10683.
6.1 LEVELLING THE STOVE
The stove must be levelled by adjusting the feet (where featured), then checked
using a spirit level (Fig. 6.1).
A B = Spirit level
6.2 SYSTEM CONNECTIONS
6.2.1 Electrical connection
The stove is connected to the electrical system simply using the plug supplied.
The electrical connection (plug) must be easily accessible when the stove is installed.
If the power cord is damaged it must be replaced by the technical service or a qualified
technician, to prevent any kind of risk.
6.2.1.1 Earth
The system must be earthed and fitted with a residual current circuit-breaker in
accordance with legislation in force (Fig. 6.2).
The flue must have its own earth connection.
6.2.2 Connection to an external timer thermostat
The stove can be connected to an external timer thermostat that switches the stove
on or off according to the set temperature.
When the set temperature is reached the thermostat opens the circuit and
consequently switches off the stove.
The external thermostat is connected to the two terminals on the rear of the stove,
which are jumpered in the factory. Disconnect the jumper and connect the two
thermostat contacts.
The stove must be set to configuration 1 following the instructions shown in the
paragraph on "Initial configuration".
After first installing the timer thermostat, the stove needs to be switched on manually,
while the timer thermostat is in "call" status. This operation is also required in the
event of power failures or if the stove is switched off manually.
To avoid overlapping the working time bands, it's recommend to disable (set to OFF)
the stove's timer (see par. 10.1).
6.2.3 Operation with room probe
In certain circumstances the stove may need to modulate operation based on the
temperature read by the room probe fitted on the stove.
The stove must be set to configuration 2 following the instructions shown in paragraph
6.3.
6.2.4 Connection to a storage tank with coil
The stove can be used to maintain the temperature inside a storage tank fitted with
coil.
In this case simply disconnect the external temperature probe from the stove and fit
it in the probe socket on the storage tank.
The stove must be set to configuration 3 following the instructions shown in paragraph 6.3.
6.2.5 Connection to a storage tank without coil
The stove can be used to maintain the temperature inside a storage tank without
coil.
In this case simply disconnect the external temperature probe from the stove and fit
it in the probe socket on the storage tank.
The stove must be set to configuration 4 following the instructions shown in paragraph 6.3.