Herunterladen Inhalt Inhalt Diese Seite drucken

Test Battery And Alternator; Select Operating Mode; Battery Test/Starting Capacity - ULTIMATE SPEED UAWSB 2 B1 Bedienungs- Und Sicherheitshinweise Originalbetriebsanleitung

Batterie- und lichtmaschinentester uawsb 2 b1
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 99
z Test battery and alternator
z Select operating mode
The device automatically detects whether
a 6 V or 12 V battery is connected�
If this function does not work
(e�g� discharged 12 V battery is identified
as a 6 V battery), then set the selector
switch
or 12 V, depending on the type of battery
or alternator to be tested�
z Battery test/starting capacity
If only the "very low charge" LED is lit
up, the charge status of the battery is
low� In this LED status, the electrical volt-
age in 6 Volt operating mode is approx�
5�8 Volt and in 12 Volt operating mode it
is approx� 11�5 Volt� The battery must be
recharged�
If additionally, the "half-charged" LED is
lit up, the battery is half charged� In this
LED status, the electrical voltage in 6 Volt
operating mode is approx� 6�1 Volt and
in 12 Volt operating mode it is approx�
12 Volt� We would recommend that the
battery is recharged�
If the "fully charged" LED is also lit up,
then the battery is fully charged and has
the capacity to start the vehicle� In this
LED status, the electrical voltage in 6 Volt
operating mode is approx� 6�4 Volt and
in 12 Volt operating mode it is approx�
12�6 Volt�
Attention: Learn about the
maintenance of your battery in the
operating instructions before charging
the battery!

Test battery and alternator

1
on the front of the device to 6 V
GB/CY
9

Werbung

Inhaltsverzeichnis
loading