Herunterladen Inhalt Inhalt Diese Seite drucken

Setting The First Remote Control; Limit Switch Adjustment; Setting In Mode 1 (Manual) - cherubini BLUE TRONIC RX-Serie Einstellanleitungen

Rohrmotor für rollladen mit elektronischer endlageneinstellung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 43

SeTTing The firST remoTe conTrol

This operation can only be performed when the motor is new, or after a total delete of
the memory.
T1: First remote control to be set.
During this step, power up only one motor at time!
A
+
B
B
B
T1
T1
T1 (2 sec)

limiT SwiTch adJuSTmenT

Blue Tronic RX tubular motors have an electronic limit switch system with an encoder.
This system ensures great reliability and precision in keeping the positions. Limit switch
regulation is performed simply with the remote control. During setting, the motor moves
only as long as the up or down button is pressed, stopping when the button is released. At
the end of setting, press either the up or down button briefly to move the motor.
The adjustments of the limit switches can be done in different modes depending on
whether the rolling shutter is equipped with lockdown hangers or physical stops.

SeTTing in mode 1 (manual)

In this mode it doesn't matter whether or not the rolling shutter has got physical stops in
the opening position and the lockdown hangers in the closing position. It is possible to
choose whether to set the upper limit or the lower limit first. The correct rotation direction
will only be identified after the first position is set so it is sometimes necessary to use the
"up" or "down" button.
Take note of the following two examples:
30

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis