Herunterladen Inhalt Inhalt Diese Seite drucken

Setting The First Remote Control; Automatic Disabling Of The First Remote Control Setting Function; Adjustement Of The Limit Switches - cherubini Garda RX Einstellanleitungen

Mit integriertem funkempfänger und mechanischer endabschaltung
Vorschau ausblenden Andere Handbücher für Garda RX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39

SETTING THE FIRST REMOTE CONTROL

This operation can only be performed when the motor is new, or after a total delete of
the memory.
During this step, power up only one motor at time!
T1: First remote control to be set
+
A
B
T1
AUTOMATIC DISABLING OF THE FIRST
REMOTE CONTROL SETTING FUNCTION
Every time you connect the power supply to the motor, you have 3 hours to store the
first remote control. After this time, the ability to store the remote control is disabled.
To reset the timer of the function you have to disconnect and reconnect the power
supply to the motor.
NB: Until the remote control has been memorised, the wired control of the motor
will operate in "dead-man" mode.
ADJUSTING
SCREWS
B
A
STOP RING NUT
B

ADJUSTEMENT OF THE LIMIT SWITCHES

1. To decide which adjusting screw to fix, simply watch the direction
of rotation of the stop ring nut: if the stop ring nut pulled by the
roller goes in direction A, use the adjusting screw A to set the limit
switch in that direction. If it goes to the opposite direction (B), use
the adjusting screw B.
2. Start up the awning or the rolling shutter in the direction in which
you wish to set the first limit switch. After a few turns the
motor will stop on the preset stop.
T1
3. Screw the adjusting screw suited to the
direction (see point 1.) in direction "+" till it
gets to the chosen position.
4. Invert the engine sense of direction and set
the second limit switch.
B
T1 (2 sec)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis