Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Overall Dimensions - Riello 40 FS20 CV 569 T Montage- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2.

TECHNICAL DATA

2.1 TECHNICAL DATA
TYPE
Thermal power
Natural gas
(Family 2)
Electrical supply
Motor
Capacitor
Ignition transformer
Absorbed electrical power
(1) Reference conditions:

2.2 OVERALL DIMENSIONS

350
33
Length available using a separate kit.
Combustion head extension, supplied separately.
2.3 WORKING FIELD
4.8
4.0
3.2
2.4
1.6
0.8
0
80
D5212
70,000
3216
569T
(1)
81 – 220 kW
Net heat value: 8 – 12 kWh/Nm
Pressure: min. 20 mbar
Single phase, 230 V
230V / 1.4 A
5 F
Primary
230V / 1.8 A
0.25 kW
Temp. 20°C - Barometric pressure 1013 mbar – Altitude 0 m above sea level.
Burner
120
280
 
100
120
140
90,000
110,000
130,000
-
70,000 – 189,000 kcal/h
3
-
7,000 – 10,340 kcal/Nm
-
max. 100 mbar
~
±
10%
50Hz
-
Secondary 8 kV / 30 mA
389
379
67
160
180
200
150,000
170,000
Thermal power
2
GB
3
Flange
170
D4257
220
kW
190,000
kcal/h

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

3756938

Inhaltsverzeichnis