TECHNICAL DATA

TYPE
Thermal power
Natural gas
(Family 2)
Electrical supply
Motor
Capacitor
Ignition transformer
Absorbed electrical power
For gas family 3 (LPG) ask for separate kit.
COUNTRY
GAS CATEGORY
The burner meets protection level of IP X0D (IP 40) as per EN 60529.
The burner is approved for intermittent operation as per Directive EN 676.
EC marking in accordance with Gas Appliance Directive 90/396/EEC; PIN 0063AP6680.
According to Directives: Electromagnetic Compatibility 89/336/EEC - 2004/108/EC, Low Voltage
73/23/EEC - 2006/95/EC and Machine 2006/42/EC.
Gas train according to EN 676.
1 – Air damper
2 – Damper fixing screws
3 – Grommet
4 – Fairing fixing screw
5 – Air pressure switch
6 – Motor
7 – Lockout lamp with reset button
8 – Control box
9 – 6 pole socket for gas train
10 – Capacitor
NOTES
– The grommet (3) supplied with the burner, must be fitted to the same side of the gas train.
– After having installed the burner verify the access to the fixing screws of the hood.
If necessary, replace them with the fixing screws (4, fig. 1) supplied.
3389
567M
46  93 kW
8  12 kWh/m
Pci
Pressure
min. 10 mbar – max. 40 mbar
Single phase, 230 V ± 10% ~ 50Hz
Run current 0.75 A - 2,800 rpm - 294 rad/s
4 F
primary 230 V / 0.2 A
0.15 kW
IT - GR
II2H3B/P
II2Er3P
8
9
4
3
40,000  80,000 kcal/h
– 7,000  10,340 kcal/m
3
FR
5
1
GB
ENGLISH
3
secondary 8 kV
6
10
Fig. 1
7
1
2
2
D7386