12 Initial start-up

This chapter describes the procedures you have to carry out before you can operate the A/C service unit.
12.1

Setting up and switching on

Note In order to achieve correct measurements, the A/C service unit must be placed on a level flat sur-
face during operation. Ignore any error codes which occur during commissioning
page 30) and skip by pressing
1. Wheel the A/C service unit to the workplace and lock the front wheels.
2. Mount the service hoses.
3. Set the length of the service hoses
4. Connect the A/C service unit to the power supply.
5. To switch the A/C service unit on, set the main switch to
The switch-on delay runs for 35 s and the housing is ventilated. The software version number then appears in
the display for several seconds:
Dometic Germany GmbH
ASC6400G
LE
SN000000
SW:
Software status
DB:
Database
SN:
Serial number
LF:
Language file
6. Once the start-up procedure is complete, the A/C service unit requires the selection of the refrigerant
ing the refrigerant
12.2
Selecting the refrigerant
On initial start-up the A/C service unit displays the refrigerant selection menu.
1. In the refrigerant selection menu use the cursor keys
example R153A).
Refrigerant
R-134a
R-1234yf
R-513A
2. Press
ENTER
The chosen refrigerant is displayed.
Confirm
Refrigerant
R-513A
ENTER-OK
3. Press
ENTER
Please install HP/LP
connection hose!
Once done, press OK.
ENTER-OK
10
ENTER
(Setting the length of the service hoses
SW
LE640004
DB
mgas2107
LF
mgas0081
on page 10).
to confirm.
to confirm the selection and follow the instructions in the display and provided here:
.
I
.
or
to select the desired refrigerant (in the following
Yes
No
(Troubleshooting
on page 11).
 
on
(Select-