Herunterladen Inhalt Inhalt Diese Seite drucken

Tripping Curve (Thermal Equilibrium) - wohner OMUS C14 Connect Plus Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

OMUS®C14 Operating Instructions

Tripping curve (thermal equilibrium)

The tripping characteristic represent an overview of the times after which the OMUS®C14
switches off due to an overload that has occurred. In the warm state, it is assumed that the
device previously ran in nominal operation for a longer period of time (>2h).
6
5
4
3
2
1
0
1
3
Figure 18
Tripping time (thermal equilibrium)
Table 2: Tripping time [s] (thermal equilibrium)
Page 57 of 71
5
7
9
Overcurrent factor I/I
N
I / I
N
RESISTIVE
1,2
1,5
2
3
4
5
6
7
8
9
10
11
12
13
14
15
94 641 000 B
11
13
15
TC
5.26
1.2
0.46
0.18
0.1
0.06
0.04
0.04
0.04
0.02
0.02
0.02
0.02
0.02
0.02
0.02
English.
Resistive
Revision 09.2022