NOTE: do not move or cover the heater before
it has cooled down completely.

CLEANING AND MAINTENANCE

In the event of any anomaly or if you require
spare parts, please contact our Technical
Service.
Periodic maintenance should only be carried
out by an authorised technician.
We recommend having the appliance serviced
by an authorised technician every 2 years.
Monitor the pilot flame, which must be stable.
Check if the flexible gas pipe needs to be
replaced. If necessary, obtain a new pipe and
connect it as described in the chapter "Heater
installation".
The appliance must be cleaned with the gas
valve switched off, the heater completely cold,
and using non-abrasive products. Use a cloth.
We recommend storing the heater when not in
use, in a dust-free atmosphere, covered with a
cloth or plastic cover and in a dry place.
ANOMALIES AND REPAIRS
Take the appliance to an authorised technical
support service if problems arise. Do not
try to dismantle or repair it, as this may be
dangerous.
TROUBLESHOOTING CHART
SYMPTOM
CAUSE
The heater
Empty gas
does not
cylinder.
light
Incorrectly
fitted gas
regulator.
Gas valve
not properly
opened.
The heater
The heater is
does not
not level.
stay on
Poor room
ventilation.
Low gas
level in the
cylinder.
The heater
Regulator
does not
not properly
ignite after
attached to
a cylinder
the cylinder.
change
Not enough
gas reaching
the burners.
The gas pipe
is twisted.
SOLUTION
Ensure that the
gas cylinder
has sufficient
gas level.
Ensure that
the valve
is properly
opened.
Ensure that the
heater is on a
level surface,
as it has a
tip-over switch
that shuts off
the gas.
Ensure that
the room is
sufficiently
ventilated
so that the
heater has
the necessary
level of oxygen
to keep the
heater lit.
Check cylinder
gas level.
Make sure that
the regulator
is securely
fastened.
Hold the
controller down
for the required
time MAX 15
sec.
Make sure that
the cylinder
is correctly
positioned and
the pipe is not
twisted.