Safety Devices
Caution
Safety devices protect the user and must not be
modified or bypassed.
Pressure controller
The pressure controller keeps the boiler pres-
sure during the operation as constant as possi-
ble. The heating is turned off if the maximum
operating pressure of 4 bar is reached in the boil-
er and is reactivated in case of a pressure drop
in the boiler due to steam tapping.
Safety thermostat
If the boiler thermostat fails and the appliance
overheats, then the safety thermostat turns off
the appliance.
Please contact your local KÄRCHER customer
service to arrange for the reset of the safety ther-
mostat.
Safety lock
The safety lock seals the boiler against the
steam pressure that builds up in the boiler. If the
pressure controller is defect and the steam pres-
sure in the boiler rises, a pressure control valve
in the safety lock opens, and steam is emitted
through the lock to the outside.
Please contact your local KÄRCHER customer
service before you put the appliance into opera-
tion again.

Operation

Attaching the Accessories
Illustration
Insert steering roller and transport wheels
and lock them.
Illustration
Connect the required accessories (see
Chapter "Using accessories) to the steam
gun. Insert the open end of the accessory on
the steam gun and push onto the steam gun
until the unlocking button of the steam gun
locks into place.
Illustration
Use the extension pieces if necessary. To do
so, connect one or both extension pieces to
the steam gun. Insert the required accesso-
ries on the free end of the extension piece.
Removing the Accessories
Danger
Hot water may drip out of the accessory parts
while you are detaching them! Never detach ac-
cessory parts while steam streams out - risk of
scalding!
Move the selector switch for the steam vol-
ume back (steam lever locked).
Illustration
To detach the accessory parts, press the un-
locking button and pull the items apart.
Fill up with water
Note: If you always use usual commercial dis-
tilled water it is not necessary to descale the boil-
er.
Caution
Do not use condensation water from the drier!
Do not fill in detergents or other additives!
Remove the safety cap from the device.
Completely empty the steam boiler to re-
move existing water (see Fig.
Fill the boiler with a maximum of 1 liters of
fresh tap water.
Note: You can cut down the heating-up time
by using warm water.
Screw the safety cap back onto the device.
Turning on the Appliance
Place the unit securely on a firm surface.
Caution
The appliance must not be carried during clean-
ing.
Insert the mains plug into a socket.
Both indicator lamps must illuminate.
Caution
Do not turn the appliance on without water in the
boiler. Otherwise, the appliance may overheat
(see Help with faults).
The orange indicator lamp goes out after ap-
proximately 8 minutes.
The steam cleaner is ready to use.
Adjusting the Steam Quantity
Use the selector switch for the steam volume to
regulate the discharged steam. The selector
switch has three positions:
Maximum steam volume
Reduced steam volume
No steam - child protection
Note: In this lever position, the steam le-
ver cannot be used.
Set selector switch to the required steam vol-
ume.
While operating the steam switch, always di-
rect the steam gun at a separate piece of
cloth until the steam is emitted evenly.