Herunterladen Inhalt Inhalt Diese Seite drucken

Wiring Instructions - Elektra Beckum PK 300 K Betriebs- Und Montageanleitung

Praezisionskreissaege
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

U.K Supplement to Operating Instructions for Elektra Beckum
PK 300 K Precision Circular Saw
Please note the following supplementary information associated with this machine:
1974 Woodworking Machinery Regulations
When in industrial use, this machine falls under the scope of these regulations. In the interest of health & safety of
the machine user we recommend you study and follow these regulations.
We would also draw your attention to the booklet "Woodworking Machines Regulations 1974 - Guidance on
Regulations" ref L4 (ISBN 0118855921) published by HMSO.
Rabetting, Grooving etc.
This manual is prepared for world-wide distribution. Some of the operations depicted here are prohibited by the 1974
Regulations without the use of special guards. These operations include rabetting, grooving, tenoning etc. Always
follow the 1974 Regulations.
Paragraph 4 Connection to Power Mains
230 V motor. Although the motors supplied with this machine will run safely on a 13A domestic ring main, on starting
the machine a high current of very short duration is drawn, which could cause your 13A fuse to blow. If this persists
we recommend to have the machine connected to a 16A separate radial circuit. Ensure a suitably sized fuse
matching the motor is used.
This work should be undertaken only by a qualified electrician!
Paragraphs 11.2, 11.3, 11.6, 11.7
See note above "Rabetting; Grooving etc."
If the plug, fitted to the power cable supplied with the machine, has to be changed or replaced, connect the mains lead
conductors in accordance with the following colour code.
Single-phase motors (110/115/220/230/240 volts):
Three-phase motors (220/380/400/415 volts):
Machines with a 3-phase motor are connected to power mains using a 5-pin industrial appliance-inlet/connector
according to VDE 0623/BS 4343/IEC 309.
4-wire mains lead
5-wire mains lead

Wiring Instructions

Warning: This appliance must be earthed!
Yellow/green
Blue
Brown
Yellow/green
Brown
Black
Black
Yellow/green
Brown
Black
Black
Blue
I
-
F IN DOUBT
CONSULT A QUALIFIED ELECTRICIAN
-
Earth
-
Neutral
-
Live
-
Earth
-
Phase (L1)
-
Phase (L2)
-
Phase (L3)
-
Earth
-
Phase (L1)
-
Phase (L2)
-
Phase (L3)
-
Neutral