After initial commissioning and after system restore
After the initial commissioning of the device or after installation of the Restore USB, note the following:
The Windows firewall and Windows Defender virus scanner are enabled.
Windows protocol SMBv1 is disabled.
Only TLS 1.2 is enabled.
If this requirement is not needed or cannot be met, you can find registry files on the Restore USB stick under
"Additional_Products\TLS" which enable the changeover between Microsoft Standard and PCS settings. A restart of the
system may be required after the changeover.
The device is in a workgroup and may need to be entered in a domain.
The name assigned to the computer during initial commissioning may not be changed later.
Check the settings for the time and time zone. If necessary, change these settings to values applicable for you.
A local group policy is set up during commissioning which locks an unwanted, automatic update of the Intel Onboard
Graphics driver.
To update the driver when needed, you must set it to "Not configured" (at least temporarily).
Open the Group Policy editor.
Navigate to the group policy "Guidelines for local computer->Computer configuration->Administrative templates -
>System->Device installation->Restrictions with the device installation->Prevent the installation of devices with these
device IDs".
Make a note of the entered device ID so that you can reactivate the lock after the driver has been upgraded.
Set the group policy to "Not configured" and restart your system.
After restarting, you can install the new graphics driver.
Finally, reactivate the previously disabled lock.

Entering a SIMATIC Industrial PC in a domain

Requirement
Time synchronization with an Internet server is enabled. You can find information on this in the section: Enabling/disabling
time synchronization (Page 20).

System restore

Requirement
The device must have the factory settings before a Restore package is installed. This means:
All network cables have been pulled from the device.
The only expansion cards inserted are those with which the device was delivered and the expansion cards are in the
same slots as in the delivered condition
The partitioning of the available drives in the device must mirror the factory state.
The logical names of the system partitions must be "Boot", "System", "WinRE" and "Data...", as in the delivery condition.
NOTICE
Risk of data loss
Depending on the selected restore mode, the C: system partition or the existing drive is deleted. When deleting the
entire drive, all data, user settings and existing authorizations are lost!
Make a regular backup of the contents of the C: system partition or the drives regularly and especially before the
system recovery.
Do not change the size of the system partition. The size of the system partition must be the same as in the factory
settings, i.e. 128 GB.
18
SIMATIC IPC547G
A5E42575948-AA, 05/2021