Stand-by Mode
This mode allows the automatic shutdown of the stove once it reaches the temperature set on SET.
When this happens, the stove will wait a few minutes (factory setting), after which will turn off automatically if the tem-
perature of the room in the meantime has always maintained above the set.
Once turned off as a result of this condition, the stove will automatically turn on only when the ambient temperature will
drop to 2 °C below the set temperature in the oven (example: SET=24 °C and ambient temperature = 21 °C).
If the stove is turned off for the sleep-mode, although there is an ignition programmed this will be ignored and the heater
will turn back on only to lower the temperature as explained above.
The sleep timer is instead always respected if the stove is in STAND-BY and is turned off manually by pressing the OFF
button; doing so the stove will shut down permanently rekindling not more, less than expected from the ignition weekly
programming.
Enabling stand-by mode
Press the SET (3) to access the menu and with the button
(5) reach the MENU 05 ("STAN-BY MODE"). Then press
SET (3) to access it; STAND-BY function is set by default to OFF.
To activate this feature, press
(1), on the display you will see "STAN-BY MODE ON".
Press SET (3) to confirm and then OFF (4) to leave. The STAND-BY mode is now active.
External thermostat
The stove has the possibility to interface with an external thermostat for controlling the switching on and switching off
of the heater based on the room temperature. IThe thermostat must be of the open / closed type with a clean contact.
If the thermostat carries voltage to the card causing faults, the warranty will expire.
To configure the thermostat, simply remove the jumper on the Therm clamp (see the tab on page 30)
and connect the room thermostat.
OPERATION BY A SPECIALIZED TECHNICIAN
Once switched on, the stove will remain in operation until the temperature set in the thermostat is reached.
When the contact is opened the stove will remain in modulation and the display will show ECO THERM for 5 minutes, after
which it will go to Stand-by ECO + OFF.
At the moment of a new heat request in the room (and therefore re-closing of a contact), the stove will remain in ECO ATT
mode for 10 minutes. If during this time the contact remains closed, the stove will switch on.
NOTE:
At the moment when the stove will be switched off manually or by programming, it will no longer be connected by the
thermostat.